General specifications
|
Waypoints |
4000 waypoint memory |
Routes |
128 routes (max. 512 waypoints in each route) |
Functions |
Navigation, Position, Route, Waypoint, Event Mark, Plot, Sail To, MOB, GNSS/DGNSS, Alarms, |
|
Speed Graph and Configuration |
Integrity |
The product performs RAIM calculations in accordance with IEC 61108-1 ED.2 |
Power supply |
24 V DC (-10% to +30%), CDU 13 W |
LC display |
7” ultra-bright high contrast colour touch LCD |
LEDs |
Three 3-colour LEDs indicating RAIM and alarm status |
Mounting |
- Control and Display Unit: bracket or flush mounting |
|
- Navigation Sensor: wallmounting |
GNSS receiver
|
270 channel combined L1 GPS and L1 GLONASS |
Update rate |
1 Hz default, 5 Hz max. |
Position accuracy |
GNSS* 5 m, DGNSS** 1 m (2D RMS) |
Cold start |
1 min typical |
DGNSS beacon receiver (Dual channel receiver. Manual or automatic tuning) |
Frequency |
283.5 to 325.0 kHz |
MSK bit rates |
50, 100, and 200 bps |
Cold start time |
< 1 minute typical |
Reacquisition |
< 2 seconds typical |
Sensitivity |
2,5 μV/m for 6 dB SNR @ 200 bps MSK Rate |
Interfaces
|
- RS422 (1 unidirectional output and 3 bi-directional user ports; 4,800 - 38,400 bps configurable) |
- General purpose |
3 digital in, 3 digital out |
Dimensions (W x H x D) / Weight |
|
R5 Control and display unit |
255 x 140 x 85 mm / 1.8 kg |
R4 Navigation sensor |
128 x 39 x 137 mm / 0.5 kg |
R5 Junction box |
270 x 72 x 200 mm / 0.75 kg |
Cables
|
Power/data cable to navigation sensor |
R5 Navigation Sensor Cable 2m |
Data cable to control and display unit |
R5 Signal Cable DSUB-DSUB 2m |
Power cable to control and display unit |
R5 power cable 2 m |
GNSS antenna cable (recommended) |
RG214: Max length 45 m, TNC connector |
Input NMEA
|
ACK, DBT, DPT, HDG, HDT, VHW, RTE, Rnn, THS, WPL |
Output NMEA |
|
GGA, GGA + offset, GLL, GLL + offset, GNS, GNS + offset, RMC, RMC + offset, VTG, ZDA, DTM, GBS, GRS, GSA, GST, GSV, ALR, AAM, APB, BOD, BWR, BWC/ |
BWR Auto, HSC, RMB, XTE, WPL/RTE Working, WPL, RNN Working, WPL/RTE upload |
Environmental conditions (IEC 60945 Ed4, protected) |
- Control and display unit |
-15°C to +55°C (operational) |
|
-55°C to +85°C (storage) |
- Navigation sensor |
-30°C to +70°C (operational) |
|
-40°C to +80°C (storage) |
- Junction Box |
-15?C to +55?C (Operational) |
|
-55?C to +85?C (Storage) |
Compliance with the following standards
|
IMO resolutions |
MSC.112 (73), MSC.113 (73), MSC.114 (73), MSC.115 (73), A.694 (17), MSC.191 (79) |
IEC |
61108-1 Ed. 2.0 (2003), 61108-4 Ed. 4.0 (2004), 60945 Ed. 4.0 (2002), |
|
61162-1 Ed. 4 (2010), 61108-2 Ed. 1.0 (1998), 62288 Ed. 1.0 (2008) |